Cummins Care - Electronic Service Tools

What issue are you facing?

 

 

 


Downloads failing with INLINE 7 and J1939 for older modules

Issue:

Calibration Transfers/Downloads failing with INLINE 7 and J1939 for older modules (CM570, Celect, Celect Plus, CM550,etc)

Solution:

Enable J1939 Inter-Message Delay on Cummins INLINE 7

1.       Exit INSITE, and any other application that uses the datalink Adapter.

2.       Exit the INLINE 7 Explorer by right clicking the tray icon and choosing exit.

3.       Launch CumminsValidationTool from the start menu. Note when searching the start menu: There are no spaces in the name.

4.       Select the INLINE 7 Driver and Device, and then click Settings.

5.       Under Misc, Change “J1939 Inter-Message Delay (msec)” to 10.

6.       Click Save, and then close the CumminsValidationTool. Reopen INSITE and calibration should succeed.

 

Back to Top